SERVICE RACK SPACE POWER DRAW PDU PORTS IP PRICE ($) US Colocation1 1 U 1A 1x Power Socket 1x G Port Per Request $159.00 Order now US Colocation 2 U 2A 1x Power Socket 1x G Port Per Request $259.00 Order now US Colocation 4 U 4A 1x Power Socket 1x G Port Per Request $469.00 Order now US Colocation 45 U 5KVA 40x Power Sockets Per Request $2499.00 Order now -
SERVICE RACK SPACE POWER DRAW PDU PORTS IP PRICE ($) LA Colocation 45 U 4KVA 40x Power Sockets Per Request $1999.00 Order now -
SERVICE RACK SPACE POWER DRAW PDU PORTS IP PRICE ($) HK Colocation 42 U 4KVA 24x Power Sockets Per Request $2299.00 Order now -
SERVICE RACK SPACE POWER DRAW PDU PORTS IP PRICE ($) JP Colocation 42 U 4KVA 40x Power Sockets Per Request $2299.00 Order now -
SERVICE RACK SPACE POWER DRAW PDU PORTS IP PRICE ($) KR Colocation 42 U 3KVA 28x Power Sockets Per Request $1499.00 Order now
Why Raksmart's Colo
One-Stop Service
Solution Design, Site Selection, Procurement, Integration, Rack & Stack, On-going OperationsWorld-Class Network
Agile and Intelligent Network Services Over 1T+ CapabilityExperience Team
Live Support On Full Life CycleTier3+ Data Center
Tier 3+ Level Data Centers Connected With Enterprise Level hardwareSD-WAN
Interconnect Your Data Centers, Clouds Through Dynamic SD-WANDDOS Mitigation Service
24x7 SOC Support From Experienced Security Team
Data Center Info
Silicon Valley Portland Los Angeles Japan Hong Kong Singapore Korea
-
Silicon Valley
Located at the core of Silicon Valley
4 acres, 135000 SF
Security fence around the property, single point entrance
5.4mw power capacity in N + 1 configuration, 12 sets of UPS, 11 generators
Building I 54 crahs (computer room air handler) Building II 22 crahs
Have a large number of neutral machine rooms of high-quality operators (such as CT cn2, 4134, CMI, Cu, ATT, NTT, telia, GTT, Comcast, cogent, he, zayo)
1g to 10g connection 11 Great Oaks Blvd (Silicon Valley Internet core exchange center)
Direct connection to multiple public cloud platforms, including Alibaba cloud, AWS, Google cloud platform, Microsoft azure
Swipe card, dual authentication (fingerprint and iris scanning)
Data center certification: SOC 1, SOC 2, HIPAA, PCI, ISO 27001, hitrust
24X7X365 supervision by experienced engineers
-
Portland
2n, N + 1 UPS redundancy
18mW power capacity
18mW power capacity
N + 1 air conditioning redundancy
Cold and hot isolation
100% power SLA guarantee
1.3 energy consumption pue
Multiple submarine optical cables directly connected to Asia Pacific
100-400g backbone network
3T total network capacity
There are more than 80 operators directly connected in the computer room
Layer 3, layer 4 DDoS cleaning protection
100% network SLA guarantee
-
Los Angeles
424000 square feet of machine room area
Can be half cabinet, whole cabinet, machine cage, single room design
More than 300 network operators are directly connected to 1 Wilshire in the building
Can directly connect to any2exchange, bbix Exchange Center
Multiple power suppliers
24 / 7 / 265 professional residential security
Punch card, fingerprint, barrier and other security facilities
N. N + 1, 2n UPS power guarantee
N + 1 mechanical support
100% power SLA
Advanced monitoring and control system
N + 1 air cooling and water cooling design
High efficiency UPS system
150 pounds per square foot floor load
-
Japan
Building information: 54663 SF
DC Description: Y5 is located in a 4-story steel special anti-seismic building with over 700 cabinets.
UPS system generator: the redundancy capacity is more than N + 1, which can maximize the availability of normal operation time. The infrastructure includes an uninterruptible power supply (UPS) system to prevent power spikes, surges and curtailment, as well as redundant standby diesel generator sets to provide additional operating time. With a proprietary telemetry system, the IBX engineering team can monitor all power system components on-site or remotely and respond quickly to any problems that may arise.
Security: use biometric reader for fingerprint identification, lock the dynamic lock and key lock on the cabinet, and realize full coverage access control at all entrances and exits including the cage. At the same time, the whole center, including the cage position, is equipped with closed-circuit television digital camera.
Emergency protection: all areas are equipped with fire detection system, inspiratory smoke detection and early warning system (24 x 7 x 365 all-weather monitoring), which can achieve full traceability. The technical area is equipped with main pipe pre action sprinkler system and gas fire extinguishing system.
-
Hong Kong
DC Description: L2 level IX (Internet switching center) operator is responsible for operation. Kinx IDC directly connects the broadband of major ISPs at home and abroad, so as to provide services for users. High quality network environment, its construction, infrastructure, power, air conditioning system and security facilities are extremely outstanding.
UPS system and generator: the data center is equipped with a distribution station - Ultra-high Voltage large-scale system, which can ensure the ideal power supply. UPS n + 1 composition, stable power supply, including 30 minutes batt standby time (full load). Emergency power supply system - continuous power supply within 8-12 seconds after power failure; ensure that the fuel can be used for emergency operation for more than 12 hours.
Generator: 2n design, standard power area: average 3KVA per frame, high power area: up to 9KVA per frame, multiple oil tanks with a planned capacity of 85000 liters
Security: provide 24 / 7 monitoring and guard, and conduct strict identity management through personal ID card and fingerprint verification system. NMS, what's up system and central access control are adopted to respond to various faults quickly, support members' work and provide members' traffic analysis data.
Emergency protection: the data center maintains the best temperature and humidity level (23 ± 2 ℃, 30 ~ 60%). The leakage detection cable can automatically alarm. The air conditioning (HVAC) system is optimized by installing an overhead raised floor: the power module is located at the bottom and the communication module is located at the top. The temperature regulator cools the data center and regulates the indoor air in winter. Automatic fire detection system and emergency alarm system.
-
Singapore
Building information: the total area is 26743 square meters, and the number of data layers is up to 7
DC Description: expandable it space, special architectural design, operation performance above level 3
UPS system: public power supply capacity reaches 25MVA (including existing capacity and planned capacity). In the main building, 2n static UPS is used to provide technical (it) power supply, and N + 1 redundancy is provided by UPS of diesel engine rotor engine on the extension wing.
Generator: 22kv public power supply and N + n redundancy. The main building adopts standby diesel generator to support the mechanical system, with redundancy capacity of N + 1
Security: Operation Center and 24 x 7 x 365 security patrols. Inside and outside are monitored by CCTV system, CCTV records will be kept for 31 days, and all areas are equipped with perfect intruder detection and alarm system.
Emergency protection: all areas are equipped with fire detection system, inspiratory smoke detection and early warning system (24 x 7 x 365 all-weather monitoring), which can achieve full traceability. The technical area is equipped with main pipe pre action sprinkler system and gas fire extinguishing system
-
Korea
Building information: power wiring and telecommunication wiring are completely separated. High quality copper bus of class F design is adopted. The grounding resistance is less than 0.5 Ω
DC Description: each circuit has 20A socket switch plug-in switch (equivalent to level 3), which is continuously upgraded.
UPS system: redundant public power system (n + 1)
Generator: 1500kW, N + 1 24-hour continuous operation generator, double circuit and N + 1 uninterruptible power supply system (600KVA), standby diesel generator
Security: provide security monitoring through 24-hour patrol guard and lane control, fingerprint reader, 360 degree monitoring and motion detection system, with multi-level security traps.
Emergency protection: an environmental monitoring system equipped with VESDA, FM200 fire extinguishers and multiple detection equipment can prevent false alarm. At the same time, it is equipped with carbon dioxide and dry powder fire extinguishers, and emergency operation procedures have been developed
-
Located at the core of Silicon Valley
4 acres, 135000 SF
Security fence around the property, single point entrance
5.4mw power capacity in N + 1 configuration, 12 sets of UPS, 11 generators
Building I 54 crahs (computer room air handler) Building II 22 crahs
Have a large number of neutral machine rooms of high-quality operators (such as CT cn2, 4134, CMI, Cu, ATT, NTT, telia, GTT, Comcast, cogent, he, zayo)
1g to 10g connection 11 Great Oaks Blvd (Silicon Valley Internet core exchange center)
Direct connection to multiple public cloud platforms, including Alibaba cloud, AWS, Google cloud platform, Microsoft azure
Swipe card, dual authentication (fingerprint and iris scanning)
Data center certification: SOC 1, SOC 2, HIPAA, PCI, ISO 27001, hitrust
24X7X365 supervision by experienced engineers
-
2n, N + 1 UPS redundancy
18mW power capacity
18mW power capacity
N + 1 air conditioning redundancy
Cold and hot isolation
100% power SLA guarantee
1.3 energy consumption pue
Multiple submarine optical cables directly connected to Asia Pacific
100-400g backbone network
3T total network capacity
There are more than 80 operators directly connected in the computer room
Layer 3, layer 4 DDoS cleaning protection
100% network SLA guarantee
-
424000 square feet of machine room area
Can be half cabinet, whole cabinet, machine cage, single room design
More than 300 network operators are directly connected to 1 Wilshire in the building
Can directly connect to any2exchange, bbix Exchange Center
Multiple power suppliers
24 / 7 / 265 professional residential security
Punch card, fingerprint, barrier and other security facilities
N. N + 1, 2n UPS power guarantee
N + 1 mechanical support
100% power SLA
Advanced monitoring and control system
N + 1 air cooling and water cooling design
High efficiency UPS system
150 pounds per square foot floor load
-
Building information: 54663 SF
DC Description: Y5 is located in a 4-story steel special anti-seismic building with over 700 cabinets.
UPS system generator: the redundancy capacity is more than N + 1, which can maximize the availability of normal operation time. The infrastructure includes an uninterruptible power supply (UPS) system to prevent power spikes, surges and curtailment, as well as redundant standby diesel generator sets to provide additional operating time. With a proprietary telemetry system, the IBX engineering team can monitor all power system components on-site or remotely and respond quickly to any problems that may arise.
Security: use biometric reader for fingerprint identification, lock the dynamic lock and key lock on the cabinet, and realize full coverage access control at all entrances and exits including the cage. At the same time, the whole center, including the cage position, is equipped with closed-circuit television digital camera.
Emergency protection: all areas are equipped with fire detection system, inspiratory smoke detection and early warning system (24 x 7 x 365 all-weather monitoring), which can achieve full traceability. The technical area is equipped with main pipe pre action sprinkler system and gas fire extinguishing system.
-
DC Description: L2 level IX (Internet switching center) operator is responsible for operation. Kinx IDC directly connects the broadband of major ISPs at home and abroad, so as to provide services for users. High quality network environment, its construction, infrastructure, power, air conditioning system and security facilities are extremely outstanding.
UPS system and generator: the data center is equipped with a distribution station - Ultra-high Voltage large-scale system, which can ensure the ideal power supply. UPS n + 1 composition, stable power supply, including 30 minutes batt standby time (full load). Emergency power supply system - continuous power supply within 8-12 seconds after power failure; ensure that the fuel can be used for emergency operation for more than 12 hours.
Generator: 2n design, standard power area: average 3KVA per frame, high power area: up to 9KVA per frame, multiple oil tanks with a planned capacity of 85000 liters
Security: provide 24 / 7 monitoring and guard, and conduct strict identity management through personal ID card and fingerprint verification system. NMS, what's up system and central access control are adopted to respond to various faults quickly, support members' work and provide members' traffic analysis data.
Emergency protection: the data center maintains the best temperature and humidity level (23 ± 2 ℃, 30 ~ 60%). The leakage detection cable can automatically alarm. The air conditioning (HVAC) system is optimized by installing an overhead raised floor: the power module is located at the bottom and the communication module is located at the top. The temperature regulator cools the data center and regulates the indoor air in winter. Automatic fire detection system and emergency alarm system.
-
Building information: the total area is 26743 square meters, and the number of data layers is up to 7
DC Description: expandable it space, special architectural design, operation performance above level 3
UPS system: public power supply capacity reaches 25MVA (including existing capacity and planned capacity). In the main building, 2n static UPS is used to provide technical (it) power supply, and N + 1 redundancy is provided by UPS of diesel engine rotor engine on the extension wing.
Generator: 22kv public power supply and N + n redundancy. The main building adopts standby diesel generator to support the mechanical system, with redundancy capacity of N + 1
Security: Operation Center and 24 x 7 x 365 security patrols. Inside and outside are monitored by CCTV system, CCTV records will be kept for 31 days, and all areas are equipped with perfect intruder detection and alarm system.
Emergency protection: all areas are equipped with fire detection system, inspiratory smoke detection and early warning system (24 x 7 x 365 all-weather monitoring), which can achieve full traceability. The technical area is equipped with main pipe pre action sprinkler system and gas fire extinguishing system
-
Building information: power wiring and telecommunication wiring are completely separated. High quality copper bus of class F design is adopted. The grounding resistance is less than 0.5 Ω
DC Description: each circuit has 20A socket switch plug-in switch (equivalent to level 3), which is continuously upgraded.
UPS system: redundant public power system (n + 1)
Generator: 1500kW, N + 1 24-hour continuous operation generator, double circuit and N + 1 uninterruptible power supply system (600KVA), standby diesel generator
Security: provide security monitoring through 24-hour patrol guard and lane control, fingerprint reader, 360 degree monitoring and motion detection system, with multi-level security traps.
Emergency protection: an environmental monitoring system equipped with VESDA, FM200 fire extinguishers and multiple detection equipment can prevent false alarm. At the same time, it is equipped with carbon dioxide and dry powder fire extinguishers, and emergency operation procedures have been developed